AJBXR series junction box is suitable for integrating less than two obstruction lights’ power wires and/or alarm wires.
AJBXR junction box is composed of an aluminum compartment with terminal blocks, 2-4 units of threaded hubs (common G3/4’’ or G1/2’’ or G1’’)and watertight cable glands. AJBXR’s aluminum compartment contains a screw-type terminal block with four non-fused poles and one grounding pole.
With 2/3/4 threaded hubs, there are three sub-models for connecting obstruction lights’ wires.
AJB2R
AJB3R
AJB4R
• Integrating a PHC01 photocell’s power and loads (for conduit installation)
Item | AJB2R | AJB3R | AJB4R | |||
---|---|---|---|---|---|---|
ELECTRICAL PARAMETERS | ||||||
Number of Terminals | 4 | |||||
Grounding | Yes, 2 (1 internal, 1 external) | |||||
Number of ways | 2 | 3 | 4 | |||
Number of OB Outputs | 1 Power output / 1 Alarm output / 1 Power output & 1 Alarm output | 2 Power outputs / 2 Alarm outputs / 2 Power outputs & 2 Alarm outputs | 3 Power outputs / 3 Alarm outputs / 3 Power outputs & 3 Alarm outputs | |||
Number of OB Inputs | 1 Power input / 1 Alarm input / 1 Power input & 1 Alarm input | 1-2 Power inputs / 1-2 Alarm inputs / 1 Power input & 1 Alarm input | 1-3 Power Inputs / 1-3 Alarm Outputs / 1 Power input & 1 Alarm input | |||
MECHANICAL STRUCTURE | ||||||
Enlosure | Die-casting aluminum | |||||
Number of cable glands | 2 | 3 | 4 | |||
Size of cable glands | M20/M25, Nickel plated brass | |||||
Protection | IP65 | |||||
Weight | 0.5KG | |||||
Dimension (H*W*Depth) | 233mm*120mm*80mm / 175mm*175mm*80mm | 175mm*233mm*80mm | 233mm*233mm*80mm | |||
Mounting | Wall mounting / Cable-tie mounting / conduit mounting | |||||
APPLICATIONS | ||||||
Applicable for | •1 OBL’s power wires connecting in parallel to one power input •1 OBL’s alarm wires connecting in parallel to one alarm input •1 OBL’s power and alarm wires connecting in parallel to one power input and one alarm input | •2 OBL’s power wires connecting in parallel to 1-2 power inputs •2 OBL’s alarm wires connecting in parallel to 1-2 alarm inputs •2 OBL’s power and alarm wires connecting in parallel to one power input and one alarm input •1 PHC01 photocell’s power and load | FOR CONDUIT STRUCTURE ONLY! •3 OBL’s power wires connecting in parallel to 1-2 power inputs •3 OBL’s alarm wires connecting in parallel to 1-2 alarm inputs •3 OBL’s power and alarm wires connecting in parallel to one power input and one alarm input •1 PHC01 photocell’s power and load |
Model | Size of hub thread | Number of Cable Glands | ||
---|---|---|---|---|
AJB2R | 1/2 (G1/2’’) | 0 | ||
AJB3R | 3/4 (G3/4’’) | 1 | ||
AJB4R | 1 (G1’’) | 2 | ||
3 | ||||
4 | ||||
E.g.: AJB3R-3/4-3 = AJB3R junction box, with 3 G3/4’’ threaded hubs, with 3 cable glands. |