CTRS4CBSP-AIDO AC-DC Control box for Obstruction lights

Short Description
  • Input voltage 85-265VAC, 50-60Hz
  • Output voltage 48VDC/24VDC/12VDC available
  • With up to four light outputs
  • With a photocell, bypass switch to adjust auto/manual
  • LED indicators for light, power and photocell
  • Steady/flashing adjustable
  • NO & NC alarm relay for failures of lights, power and photocell
  • Outdoor type, IP65
  • With DIN-rail terminal blocks, circuit breaker and surge protector
Compliance
Share on facebook
Share on twitter
Share on linkedin
Share on email

Overview

The CTRS4CBSP-AIDO is an obstruction lighting control box designed for controlling and monitoring RedDot LED low intensity and medium intensity aviation obstruction lights. Incorporated an AC/DC power converter, CTRS4CBSP-AIDO allows users to input AC voltage (85-265VAC) and converts to 48VDC/24VDC/12VDC for electrical safety works. The user-friendly interface is intuitive for users to monitor operation status and easily configure functions.

There are four light outputs (max. 1A load/output). Practically, for example, for input voltage 48VDC, each output connects one OM2K or F864 medium intensity light, or up to eight OL32/OL100 low intensity lights.

With a Form C dry alarm relay (NO&NC), the control box is capable of transmitting the obstruction lighting system’s failure to users’ alarm devices, when light failure, power-off or photocell failure.

A PHC01 photocell is used for automatically switching on and off the obstruction lighting system from dusk to dawn. Bypass switch on the interface panel allows users to bypass the photocell for permanently lightening or testing.

DIN-rail terminal blocks save wiring time and enhance wiring safety. A 2P circuit breaker is effective in protecting converters from overload. A surge protector enhances protection against voltage fluctuation and lightning strikes.

CTRS4CBSP-AIDO
Key Parameters

85-265VAC 50/60Hz

Optional Input Voltage

48VDC, 24VDC, 12VDC

Output Voltage

4 outputs, 1A/output

Max. OB outputs

1*contact relay for lights, power and photocell

Max. alarm outputs

Yes

Circuit Breaker

Yes

20KA SPD

IP65

Protection

Features

  • Universal AC voltage input, range 85-265VAC, 50-60Hz
  • Output voltage 48VDC/24VDC/12VDC available
  • High-quality power converter, efficiency>80%
  • On/Off main power switch
  • LED indicators for light, power and photocell
  • “Service+Service”/”Service+Standby” adjustable when double lights used
  • Four light-outputs, 1-4 selectable upon actual application
  • Each light output load maximum 1A
  • Steady/Flashing adjustable
  • External photocell with prewired shielded cable, easy to maintain
  • Bypass switch to photocell for testing or 24/7 operation
  • One dry contact relay (From C, NO&NC) for alarm output of lights, power and photocell
  • DIN-rail terminal blocks save wiring time and enhance wiring safety
  • Circuit breaker against overload and shortcircuit
  • Surge protector against voltage fluctuation and lightning strikes

Specifications

CTRS4CBSP-AIDO Technical Specifications
ItemCTRS4CBSP-AIDO Specifications
ItemCTRS4CBSP-AIDO Specifications
POWER SUPPLY
Input Voltage85-265VAC,50-60Hz
Output Voltage48VDC / 24VDC / 12VDC
Power Consumption5W
Converter Power15W – 240W, depends on total lights’ power
OPERATION
Numbers of Light Output4
Max.Load/Output1A
Flash RateSteady/Flashing(20FPM), adjustable
Photocell sensitivity200Lux
Photocell bypassAuto/Manual adjustable
Alarm typeForm C, NO & NC, dry contact relay
Numbers of Alarm Output1*contact relay for lights, power and photocell
MECHANICAL STRUCTURE
Enclosure TypeOutdoor
Enclosure MaterialSS304 / Cold-rolled steel
ProtectionIP65
Net Weight5KG
Dimension (H*W*Depth)400*300*150mm
Operation Temperature-40°C~+60°C
Operation Humidity0-95% RH non-condensing
MountingWall mounting or U-bolt mounting

Ordering Code

SeriesInput VoltageOutput VoltageNumbers of lights on top (Note1)Converter Type (Note2)Converter Power (Note3)Enclosure material
CTRS4CBSP-AIDOA220 (85-265VAC)D48 (48VDC)T1ENC (Enclosed)SS (SS304)
D24 (24VDC)T2DIN (DIN-rail)CRS (Cold-rolled steel)
D12 (12VDC)
Notes:
1) T1: one light is on top of a structure or the light functions differently from other lights, adjustable Service+Service/Service+Standby NOT applicable. T2: two lights on top of structure or two lights functions coordinately but differently from other lights, adjustable Service+Service/Service+Standby applicable.
2) Enclosed type: Image1; DIN-rail type: Image2
3) The converter’s power depends on lights’ power connected to the control box. REDDOT will offer the most suitable to customers.
E.g.: CTRS4CBSPA220D48T2-ENC100-SS = AC-DC control box, 85-265VAC input, 48VDC outoutput, Service+Service/Service+Standby applicable, with enclosed converter 100W, SS304